<bdo id="cj2vd"><small id="cj2vd"></small></bdo>

    1. <bdo id="cj2vd"></bdo>

        国语高清videossexotv_欧美亚洲色偷另类图片欧美_中文字幕人妻视频手机版_大地资源第二页中文高清版少女视频观看片TV哔哩哔哩_国产幕精品无码亚洲字幕资不卡

        產(chǎn)品展示
        PRODUCT DISPLAY

        打印當(dāng)前頁

        免費(fèi)咨詢:021-67610176

        發(fā)郵件給我們:market@hsiyen.cn

        分享到:
        產(chǎn)品展示您現(xiàn)在的位置: 首頁 > 產(chǎn)品展示 > > 美國戴安Dionex > 美國戴安 P/N: 164718Dionex Acclaim 300 C18 Column 生物色譜柱

        Dionex Acclaim 300 C18 Column 生物色譜柱

        簡要描述:

        戴安公司生產(chǎn)的儀器主要有離子色譜儀、高效液相色譜儀、快速溶劑萃取儀和氨基酸直接分析儀。其中離子色譜儀憑借著雄厚的技術(shù)優(yōu)勢(shì)和方法已廣泛地應(yīng)用于各個(gè)領(lǐng)域,其*達(dá)80%。與離子色譜相關(guān)的文章有90%均出自戴安公司生產(chǎn)的離子色譜儀。

        型號(hào) 美國戴安 P/N: 164718
        廠商性質(zhì) 代理商
        更新日期 2018-04-22

        Acclaim 300 C18 Protein and Peptide Column

        High-Resolution Separation of Proteins and Peptides

        The Acclaim? 300 features 3 ?m silica particles for rapid analysis of complex protein digests. The Acclaim 300’s stable bonding make these columns compatible with a wide variety of applications, including LC/MS methods.

        • Designed for high-resolution peptide mapping and protein separations
        • High-efficiency 3 ?m spherical silica substrate
        • High-performance bonding chemistry on 300 ? pore silica
        • Application tested for suitablility in peptide mapping
        • Reproducible for dependable results
        • LC/MS compatible

        Manufacture of these columns starts with ultrapure silica that contains minimal concentrations of metal contaminants, minimizing the tailing effects of residual, exposed silanol groups. Exhaustive bonding and end-capping techniques result in stable bonding and columns that exhibit predictable reversed-phase separations with minimal secondary interactions. 

        The use of a 3 ?m silica particle reduces limits for diffusion of the analytes into the stationary phase, resulting in fast, high-resolution separations. Compared to 5 ?m column packings, the smaller particles support increased flow rates and shallower gradients on shorter columns, for faster separations. Dionex tests each bonded silica lot for peptide selectivity to ensure reproducible performance.

        Acclaim PepMap for TFA-Free Peptide Mapping  Specifications
        Column typeNanoCapillaryMicro
        Column i.d.75 ?m300 ?m1.0 mm
        Length50, 150, 250, and 500 mm50, 150, and
        250 mm
        50, 150, and
        250 mm
        Recommended Flow Rate200 nL/min4 ?L/min40 ?L/min
        Packing MaterialC18, 100 ?,
        3 ?m
        C18, 100 ?,
        3 ?m
        C18, 100 ?,
        3 ?m
        C18, 300 ?,
        5 ?m
        C18, 300 ?,
        5 ?m
        C18, 300 ?,
        5 ?m
        C8, 100 ?,
        3 ?m 
        C8, 100 ?,
        3 ?m
        C8, 100 ?,
        3 ?m
        C8, 100 ?,
        5 ?m 
        C8, 100 ?,
        5 ?m
        C8, 100 ?,
        5 ?m
        C4, 300 ?,
        5 ?m
        C4, 300 ?,
        5 ?m
        C4, 300 ?,
        5 ?m
        ColumnFused-silicaGlass Lined TubingStainless steel
        Column Inlet1/16-in.
        PEEK sleeve adapter
        (provided)
        nanoViper (optional)
        1/16-in.
        universal fitting
        nanoViper (optional) 50?m i.d. PEEK sheathed fused silica with nanoViper fittings
        1/16-in.
        PEEK tubing
        nanoViper (optional) 75?m i.d. PEEK sheathed fused silica with nanoViper fittings
        Column OutletFused-silica
        25-?m i.d./ 280-?m o.d.
        Fused-silica
        75-?m i.d./ 280-?m o.d
        1/16-in.
        PEEK tubing
        nanoViper (optional) 75?m i.d. PEEK sheathed fused silica with nanoViper fittings
        MS Outlet1-m Length



        The standard particle size is nominally 3 ?m. Analytical columns are available in 2.1, 3.0, and 4.6 mm dimeters; standard lengths are 50 and 150 mm. Capillary formats are available in 75 and 300 ?m, 1.0 mm, and custom diameters, and in 50, 150, or 250 mm lengths. Guard columns in both 2.0 and 4.3 mm sizes are recommended to protect analytical columns.

        Analytical Columns
        Acclaim 300, C18, 3 ?m Analytical (2.1 x 50 mm)060263
        Acclaim 300, C18, 3 ?m Analytical (2.1 x 150 mm)060264
        Acclaim 300, C18, 3 ?m (3.0 x 150 mm)063684
        Acclaim 300, C18, 3 ?m Analytical (4.6 x 50 mm)060265
        Acclaim 300, C18, 3 ?m Analytical (4.6 x 150 mm)060266
        Guard Columns
        Acclaim 300,C18, 3?m, Guard Cartridges, (2.1 x 10mm), 2 ea; requires holder 069580069690
        PROD,COL,ACCLAIM,300,C18,3UM,4.6X10MM,GRD,2EA069697
        Hardware
        Acclaim SST Guard Cartridge Holder V-1059456
        Guard to Analytical Column Coupler059457
        Guard Kit (Holder and Coupler)059526
        Acclaim SST Guard Cartridge Holder V-2069580
        Acclaim Guard Kit (Holder and coupler) V-2069707
        Guard to Analytical Column Coupler V-2074188
        Micro and Nano Columns
        Acclaim PepMap100, C18, 3 μm, 100 ?, 75 μm i.d. × 5 cm, nanoViper164567
        75 ?m i.d. x 15 cm, packed with Acclaim PepMap300 C18, 5 ?m, 300?, nanoViper164708
        300 ?m i.d. x 5 cm, packed with Acclaim PepMap100 C18, 3 ?m, 100?, nanoViper164716
        300 ?m i.d. x 15 cm, packed with Acclaim PepMap300 C18, 5 ?m, 300?, nanoViper164718
        Acclaim PepMap300, C18, 5 ?m, 300 ? Wide Pore, 1.0 mm x 5 cm163584
        Acclaim PepMap100, C18, 3 μm, 100 ?, 1 mm i.d. × 15 cm, nanoViper164572


        留言框

        • 產(chǎn)品:

        • 您的單位:

        • 您的姓名:

        • 聯(lián)系電話:

        • 常用郵箱:

        • 省份:

        • 詳細(xì)地址:

        • 補(bǔ)充說明:

        • 驗(yàn)證碼:

          請(qǐng)輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7